Service Call 101-195
SC No.
Level
SC186-00
D
D146/D147/D148/D149/D150
Error Name/Error Condition/Major Cause/Solution
CIS LED error
During initialization:
§
The ratio between the average values of leading-edge area
and rear-edge area is out of specification.
§
Shading data peak value is below specification.
During scanning:
§
Shading data peak value is below specification.
Details:
During initialization:
§
Occurs when one out of two CIS LEDs is malfunctioning,
causing the difference between the average values of
leading-edge area and rear-edge area to be large (CIS LED
error detection).
§
Occurs when both of the CIS LEDs are malfunctioning
(unlit), causing the shading data peak value to be extremely
low (CIS white level adjustment).
During scanning:
§
Occurs when both of the CIS LEDs are malfunctioning
(unlit), causing the shading data peak value to be extremely
low (CIS scan control, gray balance
adjustment/confirmation).
§
The first and second consecutive occurrences of each
constitute initial/feed jams. The third occurrence constitutes
an SC.
(An initialization jam/transport jam occurs on 2 continuous
occasions during either initialization or transport, and on the 3rd
continuous occasion, an SC is generated)
During initialization:
§
One or two out of two CIS LEDs are defective
During scanning:
§
Both of the CIS LEDs are defective.