Ricoh D146 Service Manual page 566

Hide thumbs Also See for D146:
Table of Contents

Advertisement

Service Call 620-689
SC No.
Level
SC635-00
B
SC No.
Level
SC636-01
D
D146/D147/D148/D149/D150
Error Name/Error Condition/Major Cause/Solution
Counter device error 4
A backup battery error was returned by the counter device.
Counter device control board or the backup battery of counter
device defective
§
Replace the counter device control board.
§
Replace the backup battery.
Error Name/Error Condition/Major Cause/Solution
IC Card Error (Expanded authentication module error)
Issued when expanded authentication management is set to
"ON" but either of the following occur.
§
There is no expanded authentication module in the
machine.
§
The SD card or the file of the expanded authentication
module is broken.
§
There is no DESS module in the machine.
§
There is no DESS module in the machine (models on which
the function is optional).
§
There is no expanded authentication module in the
machine.
§
The SD card or the file of the expanded authentication
module is broken.
§
Set a working SD card/expanded authentication module file.
§
Install the DESS module.
§
In the SSP mode set SP5-401-160 to 0.
§
In the SSP mode, set SP5-401-161 to 0.
§
Replace the NVRAM.
5-92
SM

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

D147D149D148D150