SC No.
Level
SC535-00
D
SC No.
Level
SC540-00
D
SM
Error Name/Error Condition/Major Cause/Solution
Paper Exit Cooling Fan Lock
In the motor ON state, the value of the lock sensor is checked
every 100msec.
If a lock signal is not obtained for 50 times consecutively.
§
Motor defective
§
Connector disconnected
§
Harness broken
§
IOB defective
§
Replace the motor
§
Reset the connector
§
Replace the harness
§
Replace the IOB
§
Replace the fan
Error Name/Error Condition/Major Cause/Solution
Fusing Motor: Lock
During motor ON, after checking lock signals for 2sec, a High
level was detected at least 20 times.
§
Motor defective
§
Connector disconnected
§
Harness broken
§
IOB defective
§
Unit torque increased
§
Replace the motor
§
Reset the connector
§
Replace the harness
§
Replace the IOB
§
Replace the unit