System Power Requirements; Pdu Hardware Specifications; Table 9: Drive Enclosure Power Characteristics - Oracle FS1-2 Installation Manual

Flash storage system
Hide thumbs Also See for FS1-2:
Table of Contents

Advertisement

Table 9: Drive Enclosure power characteristics

Power
characteristic
Maximum
output power
Frequency
Voltage range
Maximum range
selection
Maximum
inrush current
Power factor
correction
Harmonics
Operating
temperature

System Power Requirements

The total power consumed by the Oracle FS1 Flash Storage System is dependent
on the configuration of the system. To determine the system electrical input
ratings for Oracle Flash Storage Systems that use the Oracle supported PDUs,
refer to the PDU information provided for Oracle Flash Storage Systems.
Oracle Flash Storage Systems require redundant input power feeds for proper
fault tolerant operation.
Note: Ensure that you have the exact power load and current requirements for
your specific Oracle FS System at hand.
If non-Oracle PDUs are used, you must determine the electrical input ratings of
the Oracle FS System configuration.

PDU Hardware Specifications

The PDUs used in a not-racked Oracle FS System installation must provide
redundancy for both external AC power source and internal AC power
Value
Maximum power consumption depends on the type of Drive
Enclosure (DE2-24P or DE2-24C), its size (2U/4U), and
configuration.
4U HDD= 376VA (4TB HDD)
2U SFF = 260VA (900GB SFF HDD)
2U SSD = 307VA (19 x 1.6TB SSD)
50–60 Hz
100–240 Volts AC rated
47–63 Hz
20A
95% or less at nominal input voltage
Meets EN61000-3-2
5° –40° Celsius (41° —104° Fahrenheit)
Oracle FS Systems: Installation Overview
23