Default Configuration
No alarms are configured.
Command Mode
Global Configuration mode
User Guidelines
This command has no user guidelines.
Example
The following example configures the following alarm conditions:
•
Alarm index — 1
•
Variable identifier — 1.3.6.1.2.1.2.2.1.10.5
•
Sample interval — 10 seconds
•
Rising threshold — 500000
•
Falling threshold — 10
•
Rising threshold event index — 1
•
Falling threshold event index — 1
console(config)#rmon alarm 1 1.3.6.1.2.1.2.2.1.1.10.5 10 50000 10 1 1
rmon collection history
Use the rmon collection history command in Interface Configuration mode
to enable a Remote Monitoring (RMON) MIB history statistics group on an
interface. To remove a specified RMON history statistics group, use the no
form of this command. Also see the
Syntax
rmon collection history
seconds
[interval
no rmon collection history
index — The requested statistics index group. (Range: 1–65535)
•
index
[owner
]
index
show rmon collection history
ownername
] [buckets
RMON Commands
command.
bucket-number
]
1541