4-8.

ELEVATOR ASSEMBLY

4-8-1.

ELEVATOR MODULE

Preliminary
1. Remove the SUPPLY CARTRIDGE.
2. De--energize the IMAGER, but do not disconnect the POWER CORD yet.
3. Actuate the SERVICE SWITCH by unscrewing the ACTUATOR SCREW.
4. Open the FRONT DOOR. Energize the IMAGER while observing the ELEVATOR from the front of the
IMAGER. The ELEVATOR will begin moving to its down position.
!
Warning
When the POWER CORD is plugged in, hazardous voltages are present in some areas of the
IMAGER. These voltages can cause severe injury or death.
5. When the ELEVATOR is all the way down, de--energize the IMAGER and disconnect the POWER
CORD.
Disassembly
1. Disconnect the CABLE PLUG from the ELEVATOR CHASSIS (Figure 4-29).
2. Disconnect the PLUG INSERT from the ELEVATOR HOME SENSOR, and pull the WIRES out
through the side of the ELEVATOR CHASSIS.
3. Remove 2 ATTACHING SCREWS.
4. Pull the PIN and pivot the MOTOR forward so the threaded ELEVATOR SHAFT clears the
MOUNTING BASE for the ELEVATOR. Then remove the ELEVATOR MODULE from the IMAGER.
2005 July Rev. B 7F3318
Figure 4-29. Removing the ELEVATOR MODULE