4-11-6. FILM CENTERING ASSEMBLY and CENTERING MOTOR (Step 7)
!
Warning
When the POWER CORD is plugged in, hazardous voltages are present in some areas of the
IMAGER. These voltages can cause severe injury or death.
1. Remove the SUPPLY CARTRIDGE.
2. De-energize the IMAGER and disconnect the POWER CORD.
3. Remove the REAR PANEL.
4. Disconnect the MOTOR ELECTRICAL CONNECTOR from the CHASSIS (Figure 4-45).
5. Cut the TIE-WRAP to free the ELECTRICAL CABLE to the MOTOR.
6. Insert a PHILLPS SCREWDRIVER through the small access holes in the end of the IMAGING
MODULE and remove 2 SCREWS.
7. Carefully rotate the CENTERING ASSEMBLY and remove it.
8. To remove the CENTERING MOTOR:
a. Remove the E-RING.
b. Remove 2 SCREWS to free the MOTOR, SHAFT, and END PLATE.
c. Remove 2 SCREWS to free the MOTOR from the END PLATE.
d. Remove the SHAFT from the MOTOR.
9. Reassemble in the reverse order of disassembly.
Figure 4-45. Replacing the FILM CENTERING ASSEMBLY and MOTOR
2005 July Rev. B 7F3318
6
7
CENTERING
MOTOR
4
Access Holes for SCREWDRIVER
END PLATE
8d
8b
Section 4 - - Disassembly/Reassembly
8a
8c
4-51