Service Manual
4-11-10. VIBRATION MOUNTS
Preliminary
1. Remove the SUPPLY CARTRIDGE.
!
Warning
When the POWER CORD is plugged in, hazardous voltages are present in some areas of the
IMAGER. These voltages can cause severe injury or death.
2. De-energize the IMAGER and disconnect the POWER CORD.
3. Remove the IMAGING MODULE from the IMAGER (4-11-1).
Note
While the IMAGING MODULE is outside the IMAGER, cover the top to avoid introducing dust or
debris that may affect image quality.
Disassembly
1. Remove the 8 HEX NUTS (8-32) securing the VIBRATION MOUNTS to the PLATEN SUPPORT
ASSEMBLY (see Figure 4-49).
2. Disconnect the GROUND STRAP at one end.
3. Remove the 4 PLATEN SHOULDER SCREWS (M6) from the corners of the PLATEN SUPPORT
ASSEMBLY, and remove the PLATEN SUPPORT ASSEMBLY from the PLATEN ASSEMBLY.
4. Unscrew the 8 VIBRATION MOUNTS from the ISOLATOR BRACKETS attached to the PLATEN
CHASSIS.
Reassembly
1. Install the 8 replacement VIBRATION MOUNTS into the ISOLATOR BRACKETS. Tighten them so
they are snug.
2. Carefully place the PLATEN ASSEMBLY onto the SUPPORT ASSEMBLY while guiding the 8
VIBRATION MOUNTS into the holes of the SUPPORT ASSEMBLY.
3. Install the 4 SHOULDER SCREWS.
4. Secure the PLATEN SUPPORT ASSEMBLY to the VIBRATION MOUNTS with the 8 HEX NUTS.
5. Reattach the GROUND STRAP.
4-56