Rollback Motor (Dcm1) - Kodak DryView 8150 Service Manual

Laser imager
Hide thumbs Also See for DryView 8150:
Table of Contents

Advertisement

4-7-2.

ROLLBACK MOTOR (DCM1)

1. Remove the SUPPLY CARTRIDGE, de--energize the IMAGER, and remove the ROLLBACK MODULE
(4-7-1).
!
Warning
When the POWER CORD is plugged in, hazardous voltages are present in some areas of the
IMAGER. These voltages can cause severe injury or death.
2. Turn the ROLLBACK KNOB to position the ROLLBACK MOTOR for easy access to its ATTACHING
SCREWS.
3. Remove 3 SCREWS to free the ROLLBACK MOTOR from its COUPLER BRACKET (Figure 4-23).
Note
To access the BOTTOM SCREW you will have to lift up the ROLLBACK ROLLER.
4. Remove the COUPLER VANE from the BRACKET.
5. Reassembly is essentially the reverse of disassembly.
!
Caution
Do not damage wiring when you install the ROLLBACK MODULE in the IMAGER. Make sure all
CABLES are routed properly after reassembly.
2005 July Rev. B 7F3318
Figure 4-23. Removing the ROLLBACK MOTOR
Section 4 - - Disassembly/Reassembly
4-27

Advertisement

Table of Contents
loading

Table of Contents