SERVICE PROGRAM MODE
5.1.4 TEST PATTERN PRINTING (SP2902-3)
NOTE: Always print a test pattern to confirm correct operation of the machine.
1. Enter the SP mode and select SP2902 003.
2. Enter the number for the test pattern that you want to print and press
the tables below.)
3. Press Copy Window to open the copy window and then select the settings for
the test print (paper size, etc.)
4. Press Start
print.
5. Press SP Mode (highlighted) to return to the SP mode display.
No.
0
None
1
Vertical Line (1dot)
2
Horizontal Line (1dot)
3
Vertical Line (2-dot)
4
Horizontal Line (2-dot)
5
Grid Pattern (1dot)
6
Independent (1-dot)
7
Independent (2-dot)
8
100% Black Coverage
9
Belt Pattern
10
Trimming Area
11
Argyle
12
Argyle (2-dot)
13
Checkered Flag
14
Horizontal Belt
15
Independent (4-dot)
16
Grayscale Horizontal
17
Grayscale Vertical
18
Grayscale Horizontal/Vertical
19
Grayscale Grid
20
Grayscale Horizontal White Stripe
21
Grayscale Vertical White Stripe
22
Grayscale Horizontal/Vertical White Stripe
23
100% White Coverage
24
Trimming Area (OR Outside Data)
NOTE: See SP 4417 in the SP table for a different set of test patterns.