NCU PARAMETERS
Address
6805A8
Acceptable CNG detection frequency
lower limit (high byte)
6805A9
Acceptable CNG detection frequency
lower limit (low byte)
6805AA
Not used
6805AB
CNG on time
6805AC
CNG off time
6805AD
Number of CNG cycles required for
detection
6805AE
Not used
6805AF
Acceptable AI short protocol tone
(800Hz) detection frequency upper
limit (high byte)
6805B0
Acceptable AI short protocol tone
(800Hz) detection frequency upper
limit (low byte)
6805B1
Acceptable AI short protocol tone
(800Hz) detection frequency lower
limit (high byte)
6805B2
Acceptable AI short protocol tone
(800Hz) detection frequency lower
limit (low byte)
6805B3
Detection time for 800 Hz AI short
protocol tone
6805B4
PSTN: Tx level from the modem
6805B5
PSTN: 1100 Hz tone transmission
level
6805B6
PSTN: 2100 Hz tone transmission
level
6805B7
PABX: Tx level from the modem
6805B8
PABX: 1100 Hz tone transmission
level
6805B9
PABX: 2100 Hz tone transmission
level
6805BD
Modem turn-on level (incoming
signal detection level)
6805BE
Not used
to
6805C6
6805C7
Bits 0 to 3 – Not used.
Bit 4 – V.34 protocol dump 0: Simple, 1: Detailed (default)
Bits 5 to 7 – Not used.
6805C8
Not used
to
6805D9
6805DA
T.30 T1 timer
SM
Function
91
Unit
Remarks
BCD (Hz)
If both addresses contain
FF(H), tone detection is
disabled.
Do not change the
setting.
20 ms
Factory setting: 500 ms
20 ms
Factory setting: 3000 ms
The data is coded in the
same way as address
680533.
Do not change the
settings.
Hz (BCD)
If both addresses contain
FF(H), tone detection is
disabled.
Hz(BCD)
If both addresses contain
FF(H), tone detection is
disabled.
20 ms
Factory setting: 360 ms
-N – 3 dBm
SP2-103-002 (parameter
01).
- N 6805B4 - 0.5N 6805B5 –3.5 (dB)
See Note 7.
- N6805B4 - 0.5N 6805B6 –3 (dB)
See Note 7.
- dBm
- N 6805B7 - 0.5N 6805B8 (dB)
- N 6805B7 - 0.5N 6805B9 (dB)
-37-0.5N
(dBm)
Do not change the
settings.
Do not change the
settings.
1 s
B766