1105*
Fusing Temperature Adjustment
1105 1
Roller Center
1105 2
Roller Ends
1105 3
Energy Saver
1105 4
Thick Paper - Center
1105 5
Thick Paper - Ends
1105 6
After Warming-up - Center
1105 7
After Warming-up - Ends
1105 8
After Warming-up - No. of
Pages
1105 9
After Warming-up - Times
1106
Fusing Temp. Display
1106 1
Roller Center
1106 2
Roller Ends
1106 3
In the Machine at Power On
1108*
Fusing Soft Start Setting
Selects whether the fusing temperature control cycle is 1 or 3 seconds.
If this is "1 (3 s)", the power supply fluctuation caused by the fusing lamp turning
on is less often.
[0 = 1 s / 1 = 2 s]
Default: 0 = N. America, Taiwan, 1 = Europe/Asia
1109
Fusing Nip Band Check
Checks the fusing nip band ( 5.1.11)
[1 = Start / 0 = Stop]
SM
SERVICE PROGRAM MODE
Adjusts the fusing temperature at the center and
both ends of the hot roller for normal printing.
[120 ~ 200 / 180 / 1°C/step]
Adjusts the fusing temperature at the center and
both ends of the hot roller for energy saver mode.
[0 ~ 160 / 150 / 1°C/step]
Adjusts the additional fusing temperature for thick
paper for the 2nd paper tray and for the bypass tray.
[0 ~ 30 / 15 / 1°C/step]
Adjusts the fusing temperature at the center of the
hot roller after the machine has warmed up.
[120 ~ 200 / 180 / 1°C/step]
Adjusts the fusing temperature at both ends of the
hot roller after the machine has warmed up.
[120 ~ 200 / 185 / 1°C/step]
In this machine, fusing temperature is kept 10°C
higher than the normal temperature for a number of
pages after the machine has warmed up. This SP
selects the number of pages made at this
temperature. See Detailed Section Descriptions –
Fusing for more details.
[0 ~ 10 / 3 / 1 page/step]
In this machine, fusing temperature is kept 10°C
higher than the normal temperature for a short while
after the machine been warmed up. This SP selects
the length of time that this temperature is used. See
Detailed Section Descriptions – Fusing for more
details.
[0 ~ 180 / 60 / 1s/step]
Displays the fusing temperature for the center or
both ends of the hot roller.
Displays the temperature in the machine at power
on.
This temperature is monitored by the thermistor on
the SBCU board.
5-7