Ricoh B205 Service Manual page 665

Hide thumbs Also See for B205:
Table of Contents

Advertisement

ERROR CODES
Code
Meaning
2-11
Only one V.21 connection
flag was received
2-12
Modem clock irregularity
2-13
Modem initialization error
2-23
JBIG compression or
reconstruction error
2-24
JBIG ASIC error
2-25
JBIG data reconstruction
error (BIH error)
2-26
JBIG data reconstruction
error (Float marker error)
2-27
JBIG data reconstruction
error (End marker error)
2-28
JBIG data reconstruction
error (Timeout)
2-29
JBIG trailing edge maker
error
2-50
The machine resets itself for
a fatal FCU system error
2-51
The machine resets itself
because of a fatal
communication error
2-53
Snd msg() in the manual
task is an error because the
mailbox for the operation
task is full.
4-01
Line current was cut
4-10
Communication failed
because of an ID Code
mismatch (Closed Network)
or Tel. No./CSI mismatch
(Protection against Wrong
Connections)
5-10
DCR timer expired
5-20
Storage impossible because
of a lack of memory
5-21
Memory overflow
5-23
Print data error when
printing a substitute rx or
confidential rx message
5-25
SAF file access error
SM
Suggested Cause/Action
Replace the FCU.
Replace the FCU.
• Turn off the machine, then turn it back on.
• Update the modem ROM.
Replace the FCU.
• Turn off the machine, then turn it back on.
Replace the EXFUNC board if the error is
frequent.
• Turn off the machine, then turn it back on.
Replace the EXFUNC board if the error is
frequent.
• JBIG data error
• Check the sender's JBIG function.
Update the MBU ROM.
• FCU defective
Check the destination device.
If this is frequent, update the ROM, or replace the
FCU.
If this is frequent, update the ROM, or replace the
FCU.
The user did the same operation many times, and
this gave too much load to the machine.
• Check the line connector.
• Check the connection between FCU and NCU.
• Check for line problems.
Replace the FCU or the NCU.
• Get the ID Codes the same and/or the CSIs
programmed correctly, then resend.
The machine at the other end may be defective.
Replace the FCU.
• Temporary memory shortage.
• Test the SAF memory.
Replace the FCU or optional EXMEM board
• Test the SAF memory.
• Ask the other end to resend the message.
Replace the FCU or optional EXMEM board.
Replace the FCU or EXMEM board.
15
B766

Advertisement

Table of Contents
loading

This manual is also suitable for:

B209D007D008

Table of Contents