3.5.4 ORIGINAL SIZE SENSORS

[B]
[A]
1. Remove the exposure glass. (
3.5.1)
2. Remove the lens cover. ( 3.5.3)
3. Remove the original width sensor [A] (
x1,
x1).
4. Remove the lens block. ( 3.5.3)
5. Remove the original length sensors [B] (
x1,
x1 ea.).