BY-PASS FEED UNIT INSTALLATION
[D]
[C]
3. Install the unit holder [A] using the Allen key (
NOTE: 1) Make sure that the four screws are tightened in the proper order, as
shown above. Otherwise, when the optional duplex unit (B414) is
installed, it will not properly lock in place.
2) After securing the unit, store the Allen key in the inner cover [B] for
future use.
4. If the optional duplex unit (B414) will be installed: Remove the indicated
parts [C] of the by-pass tray unit [D].
5. Install the by-pass tray unit (
6. Turn the main power switch on and check the by-pass tray function.
7. Make a copy from the by-pass tray. Then check the registration.
B205/B209/D007/D008
[A]
[C]
x 2,
x 1).
1-40
[B]
x 4 ).
[D]
SM