FrameMaker Ver.5.5(PC) EP1054/EP1085/EP2030 DIS/REASSEMBLY, ADJUSTMENT
98.04.13

(2) Cleaning of the Main Erase Lamp

1139D166AA
1139D167AA
1139D168AA

(3) Cleaning of the Image Erase Lamp

1151D034AA
1151D035AA
1. Remove four screws and PWB-A.
2. Remove three screws and HV1.
3. Unplug the connector of the Main Erase Lamp.
4. Remove the Imaging Unit.
5. Pull out the Toner Bottle Holder to the front.
6. Remove one screw and the Main Erase Lamp.
7. Using a brush or a soft cloth dampened with alco-
hol, clean the Erase Lamp.
NOTE
Do not touch the Lamp with bare hands.
1. Remove four screws and PWB-A.
2. Insert PWB-A into the copier to secure it.