C0F32: Faulty Atdc Sensor C0F33: Atdc Adjustment Failure - Minolta Di200 Service Manual

Hide thumbs Also See for Di200:
Table of Contents

Advertisement

(6)
C0F32: Faulty ATDC Sensor
C0F33: ATDC adjustment failure
ATDC Sensor UN2
Power Supply Unit PU1
1
2
UN2
3
4
C0F32,C0F33
Step
1
ATDC Sensor and Master Board are connected
properly.
2
The voltage across PJ6PU1-5 on Power Sup-
ply Unit and GND is DC5 V.
Relevant Electrical Parts
CN50
PJ18
1
1
2
2
3
3
4
4
8
8
Check
Master Board PWB-A
CN11
PWB-A
12
1
11
2
10
3
PJ6A-1 (UN2 CONTROL)
9
4
PJ6A-2 (DC24 V)
8
5
PJ6A-3 (UN2 ON)
7
6
PJ6A-4 (GND)
1
12
PJ6PU1-5 (DC5 V)
Result
NO
YES Change I/C.
NO
T-44
PU1
4011T512AA
Action
Correct connection.
Change Master Board.
Change Power Supply
Unit.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Di251Di351

Table of Contents