Programming The Queue Timeout - Nortel Norstar System Administration Manual

Compact plus release 5
Hide thumbs Also See for Norstar:
Table of Contents

Advertisement

126 Programming Hunt groups

Programming the queue timeout

Compact Plus System Administration Guide
6. Press ≠. The display shows Show group:.
7. Enter the hunt group number you want to programme (1-6).
8. Press ≠. The display shows Member extns.
9. Press ' until the display shows If busy:.
10. Press CHANGE to set the mode: BusyTone, Overflow, Queue.
11. Press ® to exit or 'to continue programming.
This setting allows you to programme the number of seconds a
call will remain in the hunt group queue before it is also routed to
the overflow position.
1. Place the programming overlay over the appropriate keys on
your programming telephone.
2. Press ≤••¤flfl‹›› (CONFIG). The
display shows Password:.
3. Press ‡¤‡fi°‡ (SAPLUS). The display shows
Terminals&Extns.
4. Press ' until the display shows System prgrming.
5. Press ≠. The display shows Hunt groups.
6. Press ≠. The display shows Show group:.
7. Enter the hunt group number you want to programme (1-6).
8. Press ≠. The display shows Member extns.
9. Press ' until the display shows Q Timeout:.
10. Press CHANGE to set the queue timeout: 15, 30, 45, 60, 120 or
180.
11. Press ® to exit or 'to continue programming.
P0607114 Issue 01

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Norstar compact plus release 5

Table of Contents