Show Command-History - Dell Force10 Z9000 Reference Manual

Ftos command line reference guide for the z9000 system ftos 9.1.(0.0)
Hide thumbs Also See for Force10 Z9000:
Table of Contents

Advertisement

6 active
7 active
8 active
-- Power Entry Modules --
Bay Status
-------------------------------------------------------
0 up
1 up
-- Fan Status --
Tray Status Temp Volt Speed PEM0 PEM1 Fan1 Fan2 Fan3
-------------------------------------------------------
0 up < 50C 12-16V low/2100-2700 RPM up up up up up
1 up < 50C 12-16V low/2100-2700 RPM up up up up up
2 up < 50C 12-16V low/2100-2700 RPM up up up up up
3 up < 50C 12-16V low/2100-2700 RPM up up up up up
Related
show linecard
Commands
show rpm
show sfm

show command-history

Display a buffered log of all commands entered by all users along with a time stamp.
C-Series, E-Series, S-Series, Z-Series
Syntax
show command-history
Defaults
none
Command Modes
Command History
Version 8.3.11.1
Version 8.1.1.0
Version 7.6.1.0
Version 7.5.1.0
Usage
One trace log message is generated for each command. No password information is saved to
Information
this file. A command-history trace log is saved to a file after an RPM failover. This file is
analyzed by the Dell Force10 TAC to help identify the root cause of an RPM failover.
Example
FTOS#show command-history
[11/20 15:47:22]: CMD-(CLI):[service password-encryption]by
default from console
[11/20 15:47:22]: CMD-(CLI):[service password-encryption
hostname Force10]by
default from console
- Repeated 3 times.
– view the line card status.
– view the RPM status.
– view the SFM status.
EXEC
EXEC Privilege
Introduced on the Z9000.
Introduced on the E-Series ExaScale.
Introduced on the S-Series.
Introduced on the C-Series and E-Series.