Chapter 9
AS/400 ASCII Troubleshooting
6. From a workstation attached to this network segment, create
an ARP entry. The Ethernet Interface IP address and hardware
or MAC address are needed. At the workstation, enter:
arp -s <ipaddress> <MACaddress>
ping <ipaddress>
7. Try to ping this IP address to see if the Ethernet Interface can
be seen on your network. If the interface does not respond,
verify you are on the same network segment as the printer and
that the ARP entry was created.
8. Telnet into the Ethernet Interface using the same IP address
as above. Log in as root with no password.
9. At system prompt, enter:
store tcpip from default
SMART
config http on
reset
NOTE: This will reset all TCP/IP settings to factory default and
10. Wait one minute for the Ethernet Interface to reset.
11. Power the printer off and then back on.
SMART
12. Wait for the "E-NET READY" message to display.
13. Set the IP address, subnet mask, and default gateway
parameters to the desired values. (See "Configuration Tools"
on page 32.)
198
reset the Ethernet Interface.