shellFlowControlEnable

Enables XON/XOFF flow control to the shell task.
Synopsis
shellflowcontrolenable
Availability
admin
Description
Use this command to enable XON/XOFF flow control to the shell task. Flow control is disabled by
default.
Because this command changes the flow control on the console serial port, it must be executed from a
session that is logged in from the console serial port. This command cannot run from a telnet session.
This setting saves in the configuration database; therefore, persistent across reboots and power cycles.
On dual control processor (CP) systems, a reboot on the standby CP is required for this command to take
effect. No action is required on the active CP.
CAUTION:
If flow control is enabled and if the console output is suspended for an extended period of
time, the switch might reboot. HP recommends disabling the flow control, using
shellFlowControlDisable.
Operands
none
Examples
To enable flow control:
switch:admin> shellflowcontrolenable
Enabling flowcontrol
flow control is now enabled
See also
shellFlowControlDisable