HP StorageWorks 2/64 - Core Switch Command Reference Manual page 366

Hp storageworks fabric os 5.x command reference guide (aa-rvhvb-te, september 2005)
Hide thumbs Also See for StorageWorks 2/64 - Core Switch:
Table of Contents

Advertisement

Examples
To display all the device information matching the given data:
switch:admin> nodefind a320
Local:
Type Pid
NL
FC4s: FCP [SEAGATE ST318452FC
Fabric Port Name: 20:14:00:60:69:80:04:79
Permanent Port Name: 22:00:00:04:cf:5d:dc:2d
Device type: Physical Target
Aliases: a320
NL
FC4s: FCP [SEAGATE ST336605FC
Fabric Port Name: 20:14:00:60:69:80:04:79
Permanent Port Name: 22:00:00:04:cf:9f:78:7b
Device type: Physical Target
Aliases: a320
NL
FC4s: FCP [SEAGATE ST336605FC
Fabric Port Name: 20:14:00:60:69:80:04:79
Permanent Port Name: 22:00:00:04:cf:9f:7d:e0
Device type: Physical Target
Aliases: a320
NL
FC4s: FCP [SEAGATE ST336605FC
Fabric Port Name: 20:14:00:60:69:80:04:79
Permanent Port Name: 22:00:00:04:cf:9f:26:7e
Device type: Physical Target
Aliases: a320
To display all the device information matching the given WWN:
switch:admin> nodefind 20:00:00:e0:8b:01:ce:d3
Remote:
Type Pid
NL
Device type: Physical Target
Aliases:
366 Fabric OS commands
COS
PortName
0314d9;
3;22:00:00:04:cf:5d:dc:2d;20:00:00:04:cf:5d:dc:2d; 0
0314d6;
3;22:00:00:04:cf:9f:78:7b;20:00:00:04:cf:9f:78:7b; 0
0314d5;
3;22:00:00:04:cf:9f:7d:e0;20:00:00:04:cf:9f:7d:e0; 0
0314d4;
3;22:00:00:04:cf:9f:26:7e;20:00:00:04:cf:9f:26:7e; 0
COS
PortName
020eef;
3;20:00:00:e0:8b:01:ce:d3;20:00:00:e0:8b:01:ce:d3;
Fabric Port Name: 20:0e:00:60:69:51:0b:ba
Permanent Port Name: 20:00:00:e0:8b:01:ce:d3
NodeName
0001]
0003]
0003]
0003]
NodeName
SCR