FRU Serial Number
Incident Count
Link Incident Description
Link Incident Type
Listener PID
Listener Port Type
Listener Port WWN
Listener Type
l
Manufacturer
Model Number
Node Parameters
Parameters
Parm
Displays the FRU serial number.
Displays the incident count. This number increases by 1 for each
incident within the individual switch.
Same as Link Incident Type.
Indicates the link incident type as one of the following:
•
Bit-error-rate threshold exceeded
•
Loss of signal or synchronization
•
NOS recognized
•
Primitive sequence timeout
•
Invalid primitive sequence for port state
Same as PID.
Same as Port Type.
Displays the channel HBA port world wide name.
Indicates the listener type as follows:
Conditiona
This port receives a link incident record if no
other recipients from the established
registration list have been chosen.
Unconditional
This port is always chosen as a recipient of a
link incident record.
Displays the manufacturer name or code.
Displays the model number.
Same as Parameters.
Displays the node type for the switch in three bytes, 0xAABBCC:
Byte AA
0x20
FC-SB-2 and updates.
Byte BB
0x0a
Switch.
Byte CC
0x00
Port number. It is dynamically assigned
whenever a link incident occurs.
Displays the incident node parameters type in three bytes,
0xAABBCC:
Byte AA
0x00
Reserved.
0x20
FC-SB-2 and updates.
0x40
Other FC-4s including FCP and updates.
0x60
FC-SB-2 and updates and other FC-4s
including FCP and updates.
0x80
FC-4 support not specified.
0xa0
Reserved.
0xc0
Reserved.
0xe0
Vendor specific.
Byte BB
0x00
Unspecified class.
0x01
Direct access storage device, if it is an storage
port; otherwise, not channel-to-channel
capable.
0x02
Magnetic tape, if it is an storage port;
otherwise, a reserved field for a channel port.
Fabric OS 5.x command reference guide 231