Service Personnel Initial Settings Table 2.9.1 (5/7) - Oki OKIOFFICE44 Service Manual

Service manual
Hide thumbs Also See for OKIOFFICE44:
Table of Contents

Advertisement

Service Personnel Initial Settings Table 2.9.1 (5/7)

T.F.
Item
No.
22
Modem attenuator
23
T/F tone attenuator
(for TEL/FAX SW)
24
MF attenuator
25
Ring duration detection time
26
CML timing
Installation Procedure
Specifications
Adjusts the attenuation (dB) for the transmit signal
power level.
Adjusting value is 0 to 15 dB in one dB steps.
Since the maximum send signal power level (dB) of
the fax is at 0 dB, you can select 0 dB to -15 dB in one
dB steps for the send signal power level.
0 to 15 dB. selectable
Note:
The send signal power level should meet
your country's regulation. Some countries
may specify the power level at a telephone
exchange.
In that case, you should subtract the speci-
fied level from the line cable attenuation to
determine the send level of your fax.
Adjusts the attenuation (dB) for the quasi-ring back
tone send signal of TEL/FAX switching.
Adjusting value is 0 to 15 dB in one dB steps.
Adjusts the attenuation (dB) for the send MF tone
power level.
Adjusting value is 0 to 15 dB in one dB steps.
Selects the minimum ring detection time
Adjusting time is 100 MS to 990 MS in 10 MS steps.
10 to 99 selectable.
For example:
(120 ms)
12 x 10 ms = 120 ms
Selects the time from end of ring to CML-ON. Ad-
justing time is 100 MS to 1900 MS in 100 MS steps.
0 to 19 selectable.
For example:
(300 ms)
03 x 100 ms = 300 ms
2 - 23
Default
10 dB
10 dB
OKIOFFICE 44
Service Manual, P/N 59276801
12
03