NCU Board (UNC5)
•
Conversion of receive data and receive signals to internal signal level
•
Conversion of send data and send signals to external signal level
•
Generation of dial pulses to telephone line
•
Detection of ringing signal
•
Detection of busy tone (conjunction with Modem unit)
•
Detection of hook up signal
•
Interface with telephone handset (option)
•
Output of send data and send signals to telephone line
•
Input of receive data and receive signals from telephone line
Power Supply Unit
048-POW (120V/230V), TLHV/OLHV Board for OKIOFFICE44
•
Conversion of main alternating current to the following direct currents:
+5V DC power supply
+8V DC/-8V DC power supply
+30V DC power supply
•
Supplying of main alternating current to fuser unit
•
Generation of medium voltages +300V, -300V, +400V, -450V and 0V
•
Generation of high voltages -1.35 kV, -0.75 kV and +3.5 kV
Memory Board (Option)
•
Memory storage for ECM operations, memory broadcast, delayed broadcast, etc.
CTR Board (PC Interface)
•
Driver circuits
HOOK Board (Option)
•
Hook switch circuit
TELU Board (Option)
This is contained within the optional handset.
•
Speech network circuit
Basic speech functions included.