5.3

Measurement

1)
Remove the AC power cord.
2)
Carry out the disassembly procedure up to Cover assembly-top, Frame assembly-scanner, and Unit-
printer.
(Refer to the Mechanical Disassembly and Reassembly in Chapter 4-1.)
3)
Connect extension cables to the R44 board.
4)
Connect the frequency counter (for clock frequency), digital voltmeter (for power voltage) and
Oscilloscope (for SIG signal). See figure 5.2.1.
5)
Reconnect the AC power code.
Main power supply is set to "ON" (PC1 ON) by loading the document on the cover-top.
(except +5V SUB)
6)
Measurement
7)
Remove the AC power code.
8)
Reverse the disassembly procedures.
Ground Terminal
Adjustments
Connector CN5-1 pin (SIG)
LC2-3 Pin
Crystal Oscillator
Figure 5.2.1 Measurement Points on R44 Board
5 - 4
Ground Terminal
Connector CN7
CN7-1, 2, 3 (+5VDC)
CN7-8 (+30VDC)
CN7-9 (–8VDC)
CN7-12 (+5VSUB)
OKIOFFICE 44
Service Manual, P/N 59276801