Tone Send Test - Oki OKIOFFICE44 Service Manual

Service manual
Hide thumbs Also See for OKIOFFICE44:
Table of Contents

Advertisement

7.1.12 Tone Send Test

Start
Perform TONE SEND TEST.
(See 6.8.)
Connect leads of frequency
counter (or oscilloscope)
across the line terminals
L1 and L2.
Tones appear at
L1 and L2?
Yes
End
Troubleshooting
Note 1:
Note 2:
No
Tones appear across Pin A8, B8 (S)
and Pin A12, B12 (0V) of CN10 (MCNT)?
Yes
Replace WN5 Board.
Solved?
No
Replace R44 Board.
7 - 19
The tonal frequency (2100 Hz) will be sequentially
sent for 5 seconds on the line terminals L1 and L2.
As an example, signal route uses the WN5 (NCU)
board.
No
Replace R44 board.
Signal route:
IC8-26 to 33 (AD0 to AD7)
IC8-1, 2
IC12-7 (S)
CN10-A8, B8 (S)
Signal route:
CN3-15, 16
T1-3, 1
CN1-3, 4
Yes
Possible cause:
CML signal
Return to section 7.1.1
Service Manual, P/N 59276801
OKIOFFICE 44