2.2

Site Selection

INSTALLATION
Precautions for Installation
(1) Fluctuation in line voltage
• 120V AC (102V to 127V)
• 230V AC (198V to 264V)
(2) Room temperature
50 to 90 degrees Fahrenheit (10 to 32 degrees Celsius)
(3) Humidity
20 to 80% RH
(4) Operating environment
Pressure: Equivalent to altitude of 2500 m and below.
(5) Exposure
Within five minutes at luminous intensity 2,000 lux (with the stacker cover opened).
(6) Required space for installation
The facsimile requires adequate space for safety and good operability.
(7) Levelness of installation surface
1 degree maximum.
(8) Other requirements
Avoid installing in any of the following places:
• A place exposed to direct sunlight
• A place near a heat source or exposed to vibration
• A dusty place
• A place in the atmosphere of acid gas, or steam etc.,
• A place exposed to quick temperature changes
Installation Procedure
2 - 3
Service Manual, P/N 59276801