Service Personnel Initial Settings Table 2.9.1 (4/7) - Oki OKIOFFICE44 Service Manual

Service manual
Hide thumbs Also See for OKIOFFICE44:
Table of Contents

Advertisement

Service Personnel Initial Settings Table 2.9.1 (4/7)

T.F.
Item
No.
16
T1 (RX), timeout value
17
T2, timeout value
18
DIS bit 32
19
Error criterion
20
Off-hook bypass
21
NL equalizer
Installation Procedure
Specifications
T1 (RX), timeout value (later)
Registers the time duration (in seconds) for which the
fax waits for the remote station's answer. This timer
starts after the DIS is transmitted, and checked this
timer by the transmission timing signal. If T1 times
out, the fax disconnects the line.
* Selects the 3 digit timer
010 to 255 sec selectable. (in one second steps)
T2, timeout value (layer)
Registers the time duration (in seconds) for which the
fax detects the EOL interval during reception of
phase C. The fax disconnects the line when EOL can
not detect within T2 timer.
* Selects the 3 digit timer
001 to 255 selectable. (in 100 ms steps)
For example: 060 x 100 ms =6 s
Specifies whether to transmit a bit 32 in DIS.
ON :
Transmits a bit 32
OFF:
Disable
Note:
Disable only if communication/compat-
ibility problems occur with older remote
machine.
Registers the threshold value whether to transmit
RTN or MCF signal when the error occurs in received
data.
00% to 99% selectable. (in one percent steps)
Allows two OKIFAX machines to be connected
back-to-back for testing purposes.
ON :
Enable
OFF:
Disable
Selects equalization for the following cable lengths:
0 km/1.8 km/3.6 km/ 7.2 km selectable.
Note:
Relative to 1700 Hz for length of 0.4 mm
diameter cable.
2 - 22
Default
035 sec.
130 sec.
10%
0 Km
OKIOFFICE 44
Service Manual, P/N 59276801
ON