Chapter 2
Before the installation, be sure to confirm the environmental conditions of the installation location of the
Printer.
Accordingly, before the Printer is delivered to the customer's site, you are recommended to inspect the
proposed installation location preliminarily based on the points listed below.
2.1
Installation environment
The environmental requirements of the installation location of the Printer are listed below.
(1) Maintain constant indoor air conditions.
Table 2-1 shows the temperature and humidity conditions of the installation location.
Environment
Temperature
Relative humidity
(no condensation)
Temperature gradient
(no condensation)
Site preparation check
Table 2-1 Environmental requirements
Operation: See Figure 2.1.
Downtime: 5-35˚C (41-95˚F)
Guaranteed image quality: 20-30 ˚C (68-86˚F)
Operation: See Figure 2.1
Downtime: 10-80% RH
Guaranteed image quality: 45-60% RH
Operation: ±10 ˚C (18˚F)/h or less
Downtime: ±20 ˚C (36˚F)/h or less
OKI Data Infotech Corporation CONFIDENTIAL
Requirements
2-1