Changing The Bcd Or Binary Mode For Counters And Timers - Omron CP1L Operation Manual

Sysmac cp series
Hide thumbs Also See for CP1L:
Table of Contents

Advertisement

Timers and Counters
4-9-3

Changing the BCD or Binary Mode for Counters and Timers

The refresh method for set values and present values for timers and counters
can be changed from BCD mode (0000 to 9999) to binary method (0000 to
FFFF) using the CX-Programmer
This setting is made in common for all tasks for all timers and counters.
1. Right-click New PLC in the project tree and select Properties .
2. Select the Execute Timer/Counter as Binary Option in the PLC Properties
Dialog Box. The timers and counters for all tasks will be executed in binary
mode.