Specifications
Type
Model
Serial
Peripheral
port
USB port
RS-232C
port,
RS-422A/485
port
Number of tasks
Scheduled
interrupt
Input
interrupt tasks
Maximum subroutine
number
Maximum jump
number
Scheduled interrupts
Clock function
Memory
Built-in flash
Backup
memory
Battery
backup
Memory Cassette
function
M CPU Units
CP1L-M60DR-A
CP1L-M40DR-A
CP1L-M60DR-D
CP1L-M40DR-D
CP1L-M60DT-A
CP1L-M40DT-A
CP1L-M60DT-D
CP1L-M40DT-D
CP1L-M60DT1-D
CP1L-M40DT1-D
Supported. (1-port USB connector, type B): Special for a Peripheral Device such as the CX-Pro-
grammer. (Set the network classification to USB in the Peripheral Device's PLC model setting.)
• Serial communications standard: USB 1.1
Ports not provided as standard equipment. (M-type CPU Unit: 2 ports max.,
L-type CPU Unit: 1 port)
The following Option Boards can be mounted:
• CP1W-CIF01: One RS-232C port
• CP1W-CIF11/CIF12: One RS-422A/485 port
Applicable communications modes (same for all of the above ports): Host Link,
NT Link (1: N mode), No-protocol, Serial PLC Link Slave, Serial PLC Link Master,
Serial Gateway (conversion to CompoWay/F, conversion to Modbus-RTU),
peripheral bus (See note.)
288 (32 cycle execution tasks and 256 interrupt tasks)
1 (interrupt task 2, fixed)
6 (interrupt tasks 140 to 145, fixed)
(High-speed counter interrupts and interrupt tasks specified by external interrupts
can also be executed.)
256
256
1
Supported.
Accuracy (monthly deviation): 4.5 min to −0.5 min (ambient temperature: 55°C),
User programs and parameters (such as the PLC Setup) are automatically saved to the flash
memory. It is also possible to save and read data memory initial data.
The data is automatically transferred to RAM when the power supply is turned ON. (Data memory
initial data, however, may or may not be transferred, depending on the selection in the PLC Setup.
The HR Area, DM Area, and counter values (flags, PV) are backed up by a battery.
Battery model: CJ1W-BAT01 (Built into the CP1L CPU Unit.)
Maximum battery service life: 5 years
Guaranteed (ambient temperature: 55°C): 13,000 hours (approx. 1.5 years)
Effective value (ambient temperature: 25°C): 43,000 hours (approx. 5 years)
A CP1W-ME05M Memory Cassette (512K words, optional) can be mounted. It can be used to
back up the following data on the CPU Unit's RAM and to transfer the data at startup.
• Data saved on Memory Cassette: User programs, parameters (such as the PLC Setup), DM
Area, data memory initial data, comment memory (CX-Programmer conversion tables, com-
ments, program indices), and FB program memory.
• Writing to Memory Cassette: By operations from the CX-Programmer.
• Reading from Memory Cassette: At startup, or by operations from the CX-Programmer.
Memory Cassette cannot be used in CP1L-J CPU Unit.
Note
Can be used as Modbus-RTU easy master function.
CP1L-M30DR-A
CP1L-L20DR-A
CP1L-M30DR-D
CP1L-L20DR-D
CP1L-M30DT-A
CP1L-L20DT-A
CP1L-M30DT-D
CP1L-L20DT-D
CP1L-M30DT1-D
CP1L-L20DT1-D
CP1L-J20DR-A
CP1L-J20DR-D
CP1L-J20DT1-D
−2.0 min to +2.0 min (ambient temperature: 25°C),
−2.5 min to +1.5 min (ambient temperature: 0°C)
Section 2-2
L CPU Units
CP1L-L14DR-A
CP1L-L10DR-A
CP1L-L14DR-D
CP1L-L10DR-D
CP1L-L14DT-A
CP1L-L10DT-A
CP1L-L14DT-D
CP1L-L10DT-D
CP1L-L14DT1-D
CP1L-L10DT1-D
CP1L-J14DR-A
CP1L-J14DR-D
CP1L-J14DT1-D
Not Support
4 (interrupt
2 (interrupt
tasks 140 to
tasks 140 to
143, fixed)
141, fixed)
49