Omron CP1L Operation Manual page 360

Sysmac cp series
Hide thumbs Also See for CP1L:
Table of Contents

Advertisement

Inverter Positioning
Setting Modbus
Communications
Registers
326
A641.00
Modbus
simple master
function not
active
Section 5-3
Slave address:
MOV
01 hex
#0001
D32200
Function code:
MOV
10 hex (write data)
#0010
D32201
Number of
MOV
communications data
#0009
bytes: 09 hex (9 bytes)
D32202
Register number of
MOV
write start data: 0001
#0001
hex
D32203
Number of write data
MOV
registers: 0002 hex
#0002
D32204
Number of attached
MOV
data bytes: 04 hex (4
#0400
bytes)
D32205
Moves bits 00 to 03 of
XFRB
D1 (Run/Stop
#0480
Command) to D32206
(register 0001) bits 08 to
D1
11.
D32206
Moves bit 00 of D10
XFRB
(Forward/Reverse
#0190
Command) to bit 09 of
D15.
D10
D15
ORs D15 and D32206
ORW
(register 0001) and
D15
stores the result in
D32206. (Reflect bit 09
D32206
of D15 in D32206
D32206
(register 0001).
Move bits 08 to 15 of D2
XFRB
(frequency command
#0808
value) to bits 00 to 07 of
D32206 (register 0001).
D2
D32206
Move bits 00 to 07 of D2
XFRB
(frequency command
#0880
value) to bits 08 to 15 of
D32207 (register 0002).
D2
D32207

Advertisement

Table of Contents
loading

Table of Contents