Omron CP1L Operation Manual page 358

Sysmac cp series
Hide thumbs Also See for CP1L:
Table of Contents

Advertisement

Inverter Positioning
Starting Inverter
Positioning
Stopping Internal Pulse
Output to the Error
Counter
Stopping Inverter
Positioning
324
Serial port 1 is used for communications with the Inverter.
0.05
Start input
PLS2(887) Settings
Setting details
Acceleration rate: 100 Hz/4 ms
Deceleration rate: 80 Hz/4 ms
Target frequency: 20,000 Hz
Number of output pulses: 600,000 pulses
Starting frequency: 100 Hz
• High-speed counter 0 (i.e., error counter 0) is used for the feedback pulse
input port.
0.06
• Internal pulse output is stopped immediately.
• Inverter positioning (i.e., the error counter) will continue to function.
Operation
Set to 0.
Error counter
0.07
• Internal pulse output is stopped immediately.
• The output value will remain at 0 until the error counter is reset.
@PLS2(887)
Inverter positioning 1
#0020
CW, relative pulses
#0000
D200
Target frequency, No. of output pulses
D300
Starting frequency
@INI
#0020
#0003
0000
Inverter
Inductive motor
Encoder
@INI
#0020
#0004
0000
Section 5-3
Address
Data
D200
0064
D201
0050
D202
4E20
D203
0000
D204
27C0
D205
0009
D300
0064
D301
0000
Port specifier
(Error counter 0: 0020 hex)
0003 hex: Stop virtual pulse output
0000 (Not used.)
Port specified (Error counter 0: 0020 hex)
0004 hex: Stop inverter positioning
0000 (Not used.)