Pulse Outputs; Overview - Omron CP1L Operation Manual

Sysmac cp series
Hide thumbs Also See for CP1L:
Table of Contents

Advertisement

Pulse Outputs

Pulse Frequency Conversion
Procedure
Restrictions
5-2
Pulse Outputs
5-2-1

Overview

The pulse frequency input to a high-speed counter can be converted to a rota-
tional speed (r/min) or the PV of the counter can be converted to the total
number of rotations. The converted value is output as 8-digit hexadecimal.
This function is supported only for high-speed counter 0.
Frequency−Rotational Speed Conversion
The rotational speed in r/min is calculated from the pulse frequency input to a
high-speed counter and the number of pulses per rotation.
Counter PV−Total Number of Rotations Conversion
The total number of rotations is calculated from the present value of the
counter and the number of pulses per rotation.
1,2,3...
1. High-speed Counter Enable/Disable Setting (Required)
Select the Use high speed counter 0 Option in the PLC Setup.
2. Pulse Input Mode Setting (Required)
Set the High-speed Counter 0 Pulse Input Mode ( Input Setting ) in the PLC
Setup.
3. Counting Mode Setting (Required)
Set the High-speed Counter 0 Counting Mode in the PLC Setup.
If ring mode counting is selected, set the Circular Max. Count (max. ring
count) in the PLC Setup.
4. Reset Method Setting (Required)
Set the High-speed Counter 0 Reset Method in the PLC Setup.
5. Execute PRV2(883) as described below (required).
Converting the Frequency to a Rotational Speed
Execute PRV2(883) with the following operands.
C: Control data (Set to 0000 for frequency-rotational speed conversion.)
P: Coefficient (pulses/rotation (hex))
D: First word for result
Converting the Counter PV to the Total Number of Rotations
Execute PRV2(883) with the following operands.
C: Control data (Set to 0001 for counter PV-total number of rotations con-
version.)
P: Coefficient (pulses/rotation (hex))
D: First word for result
Pulse frequency conversion is possible only for high-speed counter 0.
Fixed duty factor pulses can be output from the CPU Unit's built-in outputs to
perform positioning or speed control with a servo driver that accepts pulse
inputs.
■ CW/CCW Pulse Outputs or Pulse + Direction Outputs
The pulse output mode can be set to match the motor driver's pulse input
specifications.
Section 5-2
197

Advertisement

Table of Contents
loading

Table of Contents