2. Attach an ESD grounding strap to your bare wrist, and connect the other end of the strap to an ESD
grounding point.
3. Insert the appliance coupler end of the power cord into the appliance inlet on the power supply.
4. Insert the power cord plug into an external AC power source receptacle.
NOTE: Each power supply must be connected to a dedicated AC power feed and a dedicated
customer site circuit breaker. We recommend that you use a dedicated customer site circuit
breaker rated for 2 A (100 VAC) minimum or 1 A (240 VAC), or as required by local code.
5. Dress the power cord appropriately. Verify that the power cord does not block the air exhaust and
access to router components, or drape where people could trip on it.
6. Repeat Step
1
through Step
7. Observe the system LED on the router. If an AC power supply is functioning normally, the system
LED lights green steadily.
If the system LED is not lit, the power supply is not functioning normally. Repeat the cabling
procedures.

Connect DC Power to a DC-Powered ACX1000 or ACX1100 Router

To connect power to the DC-powered router, you need the following tools:
• Phillips (+) screwdriver, number 2
• ESD grounding wrist strap
• M3 screws and flat washers
• DC power source cables, minimum 14 AWG or as required by local code (not provided)
• Ring lugs, Molex 190700067 or equivalent (not provided)
The DC power supply has four terminals on the front panel, covered by a clear plastic cover.
Table 1: ACX Series DC Power System Input Voltage
Nominal Voltage
+24
5
for the remaining power supply.
Specification
Operating range: +18 to +30 VDC
13