5. Dress the power cord appropriately. Verify that the power cord does not block the air exhaust and
access to router components, or drape where people could trip on it.
6. Repeat Step
1
through Step
7. Observe the system LED on the router. If an AC power supply is functioning normally, the system LED
lights green steadily.
If the system LED is not lit, the power supply is not functioning normally. Repeat the cabling procedures.

Connect DC Power to a DC-Powered ACX2200 Router

To connect power to the DC-powered router, you need the following tools:
Phillips (+) screwdriver, number 2
ESD grounding wrist strap
M3 screws and flat washers
DC power source cables, minimum 14 AWG or as required by local code (not provided)
Ring lugs, Molex 190700067 or equivalent (not provided)
The DC power supply has four terminals on the front panel, covered by a clear plastic cover.
WARNING:
Table 1: ACX2200 DC Power System Input Voltage
Nominal Voltage
+24
–48
–60
5
for the remaining power supplies.
You must ground the router before connecting the DC power cables.
Specification
Operating range: +18 to +30 VDC
Operating range: –39 to –56 VDC
Operating range: –39 to –72 VDC