NTMW02 Meridian Mail CPU

The NTMW02 Meridian Mail CPU card can be equipped with up to two
NTMW03 4 Port Mail DSP daughterboard, each providing four ports of voice
mail (maximum eight ports). Refer to the Meridian Mail Compact
documentation for detailed descriptions and to
"Chapter 20 — Meridian Mail Compact Option installation and
maintenance" on page 193

NTMW04 DTI/PRI

The NTMW04 DTI/PRI Card supports 1.5 Mb digital trunks and can run in
free run or slave operation. Refer to the 1.5 Mb Administration and
Maintenance Guide for further details.

NTMW05 24DLC

The NTMW05 24 Port Digital Line Card supports 24 voice ports, Aries
telephone sets and M2250 Attendant Consoles.
Procedure 7
24DLC installation
1
Insert the NTMW05 card in its assigned slot.
The NTMW05 card can be installed in any peripheral equipment slot.
2
Connect an NE-A25B type 25 pair cable from the connector on the
faceplate of the NTMW05 to the cross-connect terminal.
3
Configure and enable the card using overlay programs 11 and 32.
—————————— End of Procedure ——————————
Option 11C Compact
Chapter 13 – Installing the circuit cards
for installation instructions.
Planning, Installation, Fault Clearing and CCBR Guide
Page 115 of 536