Chapter 22 — Upgrading software
Procedure 78
Using Flash Boot ROM Utility
1
If not previously done, install the Software Delivery (PCMCIA) card in
the socket in the faceplate of the System Core Card.
To install the Software Delivery card:
• Insert the Software Delivery card in slot A of the PCMCIA
socket located in the faceplate of the NTMW01 System Core
card. Gently press on the Software Delivery card until it is firmly
seated.
2
Select the method of invoking the Software Installation Program.
There are two methods of invoking the Software Installation Program:
• By using the UPGRADE command in Overlay 143 (this is the
recommended method — no SYSLOAD).
—or—
• By pressing the 'control' and 'I' keys on the keyboard when
prompted after the Software Delivery card is installed (this
method requires a SYSLOAD).
If you wish to invoke the program using Overlay 143 go to
If you wish to invoke the program when prompted go to
January 1999
Step 3