Page 426 of 536
Interference with Flexible Feature Codes
553-3121-210
Standard 3.0
Chapter 24 – Changing pre-programmed data
If the pre-programmed Flexible Feature Codes interfere with the
programming required for the Option 11C Compact system, use LD 57 to
remove the data from the system. (Default FFCs are listed
Pre-programmed data" on page
LD 57
To change one or more access codes, type in the following commands:
REQ
CHG, END
TYPE
FFC
CUST
0-31
FFCT
YES,(NO)
CODE
aaaa
AAAA
xx
CODE
<CR>
REQ
END
To remove one access code, type in the following commands:
REQ
OUT
TYPE
FFC
CUST
0-31
FFCT
YES,(NO)
ALL
NO
CODE
aaaa
AAAA
xx
CODE
<CR>
REQ
END
January 1999
363).
Change or end
FFC = Flexible feature codes
Customer Number
FFC Confirmation tone
Enter access code prompt (aaaa)
Enter the new access code prompt
(AAAA)
Return to REQ
End program
Action request
FFC = Flexible feature codes
Customer Number
FFC Confirmation tone
Remove specific access code
Enter access code prompt (aaaa)
Enter the new access code prompt
(AAAA)
Return to REQ
End program
in"Chapter 23 –