Chapter 15 – Installing and connecting SDI and Ethernet ports
Procedure 14
Connecting SDI ports on the SSC card
1
Connect the NTBK48 3-port SDI cable to the 9-pin SDI connection
at the bottom of the main cabinet.
Figure 31
Cable connection
2
Connect the system terminal to the cable marked "port 0" on the
NTBK48 3-port cable.
A Modem Eliminator Adapter is required to connect the Option 11C
Compact system to a TTY terminal.
3
If the system is to be accessed remotely, connect the system
modem to the cable marked "port 1" on the NTBK48 cable.
4
Connect the modem to an outside line.
5
Test the modem for proper operation once the system is
operating.
Note: The remaining ports can be used for other equipment such as
CDR devices or TTYs.
—————————— End of Procedure ——————————
Option 11C Compact
NTBK48 cable connection
Planning, Installation, Fault Clearing and CCBR Guide
Page 129 of 536