Meridian 1 equipment

In Meridian 1 systems, modules are stacked one on top of another to form a
column. Each column contains a pedestal, a top cap, and up to four modules
that can include the:
— NT5D21 Core/Network Module
— NT6D60 Core Module
— NT8D35 Network Module
— NT8D36 InterGroup Module
— NT8D37 Intelligent Peripheral Equipment (IPE) Module
— NT8D47 Remote Peripheral Equipment (RPE) Module
In addition, modules that house application specific equipment, such as
Meridian Mail and Meridian Link modules, can be included in a column.
Each pedestal houses a blower unit, air filter, power distribution unit (PDU),
and system monitor.
The top cap provides airflow exits, input/output (I/O) cable access, and
overhead cable-rack mounting. Thermal sensor assemblies for the column are
attached to a perforated panel, which is placed on top of the highest module
in the column, under the top cap.