Connecting The Cables - Nortel Meridian 1 Planning, Installation And Operating Instructions

Hide thumbs Also See for Meridian 1:
Table of Contents

Advertisement

Page 124 of 536

Connecting the cables

553-3121-210
Standard 3.0
Chapter 14 – Installing and connecting the cross-connect terminal
3
Attach labels on the cross-connect terminal to indicate the
terminal blocks assigned to:
• 25-pair cables from the cabinets
• telephones and consoles
• trunks
• other miscellaneous equipment
Note: If installing the BIX cross-connect system, refer to BIX
Installation and Servicing (NTP 631-4511-200) for information about
labels used with these terminal blocks.
—————————— End of Procedure ——————————
Always use caution when installing or modifying telephone lines.
Avoid installing telephone wiring during a lightning storm. Never
touch uninsulated telephone wiring unless the line has been
disconnected at the network interface.
Each NTMW08 cabinet requires up to six 25-pair cables amd each NTMW35
cabinet requires up to ten 25-pair cables. Cables are routed through the
opening at the bottom rear of the cabinet.
Procedure 13
Connecting the cables
1
Route the cables up through the opening at the bottom rear of
each cabinet.
2
Connect a 25-pair cable to connector on the faceplate of each line
and trunk card.
3
Terminate the 25-pair cables installed at the cross-connect
terminal.
Label all the cables at the cross-connect terminal blocks according to
the card slot allocation plan.
—————————— End of Procedure ——————————