Chapter 22 — Upgrading software
2
Select the method of invoking the Software Installation Program.
There are two methods of invoking the Software Installation Program:
• By using the UPGRADE command in Overlay 143 (this is the
recommended method — no SYSLOAD).
—or—
• By pressing the 'control' and 'I' keys on the keyboard when
prompted after the Software Delivery card is installed (this
method requires a SYSLOAD).
If you wish to invoke the program using Overlay 143 go to
If you wish to wish to invoke the program when prompted go to
3
Invoke the Software Installation Program using Overlay 143.
Note: Perform this step only when using the Overlay 143 to invoke the
Software Installation Program. To invoke the program during a
SYSLOAD, skip this step and do
Login to the system by entering LOGI<cr> and entering the password
in response to PASS?.
Note: The response to PASS? is unique to each system.
Then enter the following:
LD 143<cr>
UPGRADE<cr>
If
SOFTWARE INSTALLATION PROGRAM
message appears go to
If
SOFTWARE INSTALLATION PROGRAM
message does not appear repeat Step 3 (this step) and make sure
correct information is entered