4.

Installing indoor unit

4-1. Preparation

• Remove the front panel.
1) Slide until the 2 stoppers click inside.
2) Open the front panel forward and remove the string.
3) Remove the front panel.
• Remove the front grille.
1) Remove the 4 screws.
2) Pull the front grille and remove the 3 tabs.
• Remove the upper and the side casings.
1) Remove the 7 screws.
2) Slide and remove the upper casing (2 tabs).
3) Slide and remove the left and right casings (2 tabs on
• During installation, if needed, cut the slit portions using
nippers as shown in the illustration below.
[For moldings]
01_EN_3P379970-7B.indd 8
each side).
Side casing
Bottom frame
Slit portions
1)Slide the stoppers.
Open the front panel
Front grille
4 screws
Side casing
[For side piping]
Bottom frame
Slit portions
100
EDUS091558E
String
2)Remove the string.
3 tabs
Casing
Remove
front grille
Upper casing
Side
casing
7 screws
Slit portions
Side casing
8
C: 3P379970-7B
11/12/2015 13:29:46