INTELLIGENT EYE operation is useful for energy saving
„ People are detected in the sensing area�
The air conditioner is in normal operation while the
sensor is detecting human movement.
Energy saving operation
• If no presence is detected in the room for 20 minutes, the energy saving operation will start, and the INTELLIGENT EYE lamp goes off.
If human movement is detected again, the INTELLIGENT EYE lamp lights up and energy saving operation terminates.
• This operation changes the temperature by –3.6°F (–2°C) in HEAT / +3.6°F (+2°C) in COOL / +3.6°F (+2°C) in DRY operation from the set
temperature.
When the room temperature exceeds 86°F (30°C), the operation changes the temperature by +1.8°F (+1°C) in COOL / +1.8°F (+1°C) in
DRY operation from the set temperature.
• This operation decreases the airflow rate slightly in FAN operation only.
NOTE
Note on COMFORT AIRFLOW operation
• The airflow rate will be set to AUTO. If the up and down airflow direction is selected, COMFORT AIRFLOW operation will be canceled.
Notes on INTELLIGENT EYE operation
• Application range is as follows.
Vertical angle 90°
(Side view)
90°
• The sensor may not detect moving objects further than 23ft (7m) away. (Please see the application range)
• Sensor detection sensitivity changes according to the indoor unit location, the speed of passers-by, temperature range, etc.
• The sensor could also mistakenly detect pets, sunlight, fluttering curtains and light reflected off of mirrors as passers-by.
• INTELLIGENT EYE operation will not switch on during POWERFUL operation.
• NIGHT SET mode
Note on combination of COMFORT AIRFLOW operation and INTELLIGENT EYE operation
• The airflow rate will be set to AUTO. If the up and down airflow direction is selected, COMFORT AIRFLOW operation will be canceled.
Priority is given to the function of whichever button is pressed last.
01_EN_3P572320-1.indd
16
Horizontal
angle 110°
55° 55°
(Top view)
Page 20
will not switch on during use of INTELLIGENT EYE operation.
„ No people are detected in the sensing area�
The air conditioner will switch to energy saving mode after
20 minutes.