FTX-N/U, FVXS-N, FDMQ-R Series
SYSTEM
INDOOR
UNIT
OUTDOOR
UNIT
NOTE
• A short beep and 2 consecutive beeps indicate non-corresponding codes.
• To cancel the code display, hold
01_EN_3P572320-1.indd
36
„ Fault diagnosis by remote controller
• The remote controller can receive relevant error codes from the indoor unit.
1.
When
"
" blinks in the temperature display section.
2.
Press
produced�
• The code indication changes as shown below, and notifies you with a long beep.
CODE
00
NORMAL
UA
INDOOR-OUTDOOR UNIT COMBINATION FAULT
U0
REFRIGERANT SHORTAGE
U2
DROP VOLTAGE OR MAIN CIRCUIT OVERVOLTAGE
U4
FAILURE OF TRANSMISSION (BETWEEN INDOOR UNIT AND OUTDOOR UNIT)
INDOOR PCB DEFECTIVENESS
A1
HIGH PRESSURE CONTROL OR FREEZE-UP PROTECTOR
A5
A6
FAN MOTOR FAULT
C4
FAULTY HEAT EXCHANGER TEMPERATURE SENSOR
C9
FAULTY SUCTION AIR TEMPERATURE SENSOR
EA
COOLING-HEATING SWITCHING ERROR
E1
CIRCUIT BOARD FAULT
OL STARTED
E5
FAULTY COMPRESSOR START UP
E6
E7
DC FAN MOTOR FAULT
E8
OVERCURRENT INPUT
F3
HIGH TEMPERATURE DISCHARGE PIPE CONTROL
F6
HIGH PRESSURE CONTROL (IN COOLING)
H0
SENSOR FAULT
OPERATION HALT DUE TO FAULTY POSITION DETECTION SENSOR
H6
DC CURRENT SENSOR FAULT
H8
H9
FAULTY SUCTION AIR TEMPERATURE SENSOR
J3
FAULTY DISCHARGE PIPE TEMPERATURE SENSOR
J6
FAULTY HEAT EXCHANGER TEMPERATURE SENSOR
L3
ELECTRICAL PARTS HEAT FAULT
L4
HIGH TEMPERATURE AT INVERTER CIRCUIT HEATSINK
OUTPUT OVERCURRENT
L5
FAULTY INVERTER CIRCUIT HEATSINK TEMPERATURE SENSOR
P4
down for about 5 seconds. The code display also clears if no button is pressed for 1 minute.
is held down for about 5 seconds,
repeatedly until a long beep is
MEANING
251
EDUS091558E
When the Need Arises
36
3P572320-1
2019/06/10
17:01:18