FTX-N/U, FVXS-N, FDMQ-R Series
15/18/24 class
[Method of mounting conduit]
1) Dismount the service lid by removing the 2 screws.
2) Pass wires through the conduit and secure them with a lock nut.
3) After completing the work, reattach the service lid to its original position.
1
2
L
1
L
2
Conduit mounting plate
Lock nut
CAUTION
Precautions to be taken for power supply wiring
• When using stranded wires, make sure to use the round crimp-style
terminal for connection to the power supply terminal block.
• When connecting the inter-unit wires to the terminal block using a single core wire, be sure to curl the end of the lead.
Improper work may cause heat and fires.
01_EN_3P379970-10C.indd 10
Power supply
terminal block
3
Shape wires so
that the protection
plate and conduit
mounting plate fit
securely.
Conduit
Flat washer
Screw
A
Round
crimp-style
terminal
Good
Wrong
Stripping wire at terminal block
1
2
3
Round crimp-style
terminal
Screw
Round crimp-
style terminal
Flat washer
Good
Wrong
A
Arrow view
Excessive strip length
Strip wire end
may cause electric shock
or current leakage.
to this point.
Good
175
EDUS091558E
Service lid
Screws
Stranded wire
Screw
Flat washer
Round crimp-
style terminal
Wrong
10