FTX-N/U, FVXS-N, FDMQ-R Series
3. Attach the upper part of remote controller.
(Install the upper part on the lower part being careful parts
are facing in the correct direction. After installation, turn on
the power, and test emergency run button.)
Upper part
NOTE
1. The control box and wiring are not included.
2. Do not directly touch the PC-board with your hand.
4-7. Setting the address of wireless remote controller
(It is factory set to "1".)
<Setting from the remote controller>
Mode
Address
Multiple setting
(1) Hold down the "
button for at least 4 seconds to get the FIELD SET
MODE. (Indicated in the display area in the figure at top.)
(2) Press the "
FAN
(A/b). Each time the button is pressed the display
switches between "A" and "b".
5
Emergency run button
Upper part
ON OFF
TEMP
(3)
TIME
SETTING
UP
DOWN
FAN
(2)
RESERVE CANCEL
TIMER
(4)
MODE
(1)
TEST
(5)
" button and the "
"
TEST
" button and select a multiple setting
(3) Press the "
" button and "
UP
address.
Address can be set from 1 to 6, but set it from 1 to 3 and
to same address as the receiver. (The receiver does
not work with address from 4 to 6.)
(4) Press the "
" button to enter the setting.
RESERVE
(5) Push the "
" button to quit the FIELD SET
TEST
MODE and return to the normal display.
<Multiple settings A/b>
When the indoor unit is being operating by outside control (cen-
tral remote controller, etc.), it sometimes does not respond to
ON/OFF and temperature setting commands from this remote
controller. Check what setting the customer wants and make the
multiple setting as shown below.
Remote controller
Multiple setting
Remote control-
ler display
A: Standard
All items dis-
played.
b: Multi System Operations remain
displayed shortly
after execution
4-8. Stick the Unit No. label on the receiver and the back of
the wireless remote controller.
Unit No. label (5)
Wireless remote
controller (2)
CAUTION
Set the Unit No. of the receiver and the wireless remote con-
troller to be equal. If the settings differ, the signal from the
remote controller cannot be transmitted.
152
EDUS091558E
" button to set the
DOWN
Indoor unit
To control other
For other than
air conditions
on left
and units
Commands other
than ON/OFF
and temperature
setting accepted.
(1 LONG BEEP
or 3 SHORT
BEEPS emitted)
All commands accepted.
(2 SHORT BEEPS)
3P510049-1A