FTX-N/U, FVXS-N, FDMQ-R Series
01_EN_3P510048-1A.fm Page 8 Wednesday, December 27, 2017 2:27 AM
For example.
ON OFF
TEMP
TIME
F
UP
DOWN
FAN
RESERVE CANCEL
hr.
TIMER
hr.
MODE
NOTE
• After the timer is programmed, the display shows the remain-
ing time.
HOW TO SET MASTER REMOTE CONTROLLER
(For VRV system)
• When the system is installed as shown below, it is necessary
to designate the master remote controller.
For Heat pump system
When 1 outdoor unit is connected with several indoor units.
Outdoor unit
One of these remote controllers needs to be
designated as the master remote controller.
For Heat recovery system
When 1 BS unit is connected with several indoor units.
Outdoor unit
BS unit
One of these remote controllers needs to be
designated as the master remote controller.
• Only the master remote controller can select HEATING,
COOLING or AUTOMATIC OPERATION.
8
When the timer is programmed to
stop the system after 3 hours and
start the system after 4 hours, the
system will stop after 3 hours and
then 1 hour later the system will start.
Indoor unit
Indoor unit
When the indoor unit with master remote controller is set to
"COOL", you can switch over operation mode between "FAN",
"DRY" and "COOL".
When the indoor unit with master remote controller is set to
"HEAT", you can switch over operation mode between "FAN"
and "HEAT".
When the indoor unit with master remote controller is set to
"FAN", you cannot switch operation mode.
1 long beep .............. When attempting settings than that con-
sented above.
Only with Heat recovery system, you can
set the indoor unit to AUTOMATIC.
Attempting to do so.
How to designate the master remote controller
Operate in the following order.
1
MODE
Continuously press the OPERATION MODE SELEC-
TOR button for 4 seconds.
The displays showing "
" of all slave indoor unit connected to
the same outdoor unit or BS unit flash.
2
MODE
Press the OPERATION MODE SELECTOR button to
the indoor unit that you wish to designate as the mas-
ter remote controller. Then designation is completed.
This indoor unit is designated as the master remote
controller and the display showing "
• To change settings, repeat steps
EMERGENCY OPERATION
When the remote controller does not
work due to battery failure or the
absence there of, use this switch which
is located beside the discharge grille on
the indoor unit. When the remote con-
troller does not work, but the battery low
indicator on it is not lit, contact your
dealer.
[START]
1
Press the EMERGENCY OPERATION
switch.
The machine runs in the previous mode.
[STOP]
2
Press the EMERGENCY OPERATION
switch again.
PRECAUTIONS FOR GROUP CONTROL SYSTEM
OR 2 REMOTE CONTROLLERS CONTROL SYSTEM
This system provides 2 other control systems beside individual
control (1 remote controller controls 1 indoor unit) system. Confirm
the following if your unit is of the following control system type.
349
EDUS091558E
" vanishes.
and
.
1
2
1
2
3P510048-1A